We're Open!

Thermann Heat Pumps

Heat pumps extract heat from the surrounding environment and use it to warm water in a tank.
Therman Integrated Heat Pump

INTEGRATED HEAT PUMP

Thermann Integrated Heat Pump

Specification Thermann Integrated Heat Pump 220L
Model Thermann Integrated Heat Pump 220L
Tank Capacity 220 Litres
People Served 2–5
Power Supply 240V / 50Hz
Refrigerant Type R134a
Element Size 1.8kW
COP Up to 4.5
Installation Outdoor only
Dimensions (H x D) 1960mm x 640mm
Weight (empty) 105 kg
Warranty – Cylinder 5 years
Warranty – Parts & Labour 2 years

Features

  • Energy Efficient: Uses ambient air to heat water, significantly reducing energy consumption.
  • Government Rebate Eligible: May qualify for STCs and other local energy efficiency incentives.
  • Quiet Operation: Designed for minimal operational noise.
  • Environmentally Friendly: Low-GWP refrigerants and efficient technology reduce carbon footprint.
  • Durable Design: Built for Australian conditions with corrosion-resistant tank and housing.

Additional Information

Pressure Relief Valve Setting: 1000 kPa
Expansion Control Valve Setting: 850 kPa

Maximum Supply Pressure:

  • With ECV: 680 kPa
  • Without ECV: 800 kPa
Thermann-Split-heat-pump

SPLIT HEAT PUMP

Specification Thermann Split Heat Pump 300L
Model Thermann Split Heat Pump 300L
Tank Capacity 300 Litres
People Served 3–6
Power Supply 240V / 50Hz
Refrigerant Type R290
Element Size 1.8kW
COP Up to 4.8
Installation Outdoor condenser, indoor tank
Dimensions (Tank) 1762mm x 620mm
Dimensions (Compressor) 745mm x 480mm x 300mm
Weight (empty tank) 105 kg
Warranty – Cylinder 7 years
Warranty – Parts & Labour 2 years

Features

  • Energy Efficient: Uses ambient air to heat water, significantly reducing energy consumption.
  • Government Rebate Eligible: May qualify for STCs and other local energy efficiency incentives.
  • Quiet Operation: Designed for minimal operational noise.
  • Environmentally Friendly: Low-GWP refrigerants and efficient technology reduce carbon footprint.
  • Durable Design: Built for Australian conditions, with corrosion-resistant tank and housing.

Additional Information

Pressure Relief Valve Setting: 1000 kPa
Expansion Control Valve Setting: 850 kPa

Maximum Supply Pressure:

  • With ECV: 680 kPa
  • Without ECV: 800 kPa

Ready for Reliable Hot Water?

Whether your system has failed, you’re planning an upgrade, or simply need honest advice — we’re here to help.